A guide from P.L. Light Systems explains how growers can measure light intensity and spectral output to assess supplemental lighting in greenhouses. It recommends calibrated, professional-grade instruments and consistent readings, while noting that fixture age, installation and environmental conditions can affect results.
P.L. Light Systems has published guidance for growers measuring supplemental lighting, advising them to track both photosynthetic light intensity and spectral output rather than relying on fixture specifications alone. The measurements can help identify uneven coverage and changes in fixture performance, although the guide does not provide a universal testing schedule or a quantified yield guarantee.
Get garden gear delivered free with Prime
- Fast, free delivery on millions of items
- Prime Video, Amazon Music and more included
- Member-only deals all year
According to the P.L. Light Systems guide, plants’ usable photosynthetic light is measured as photosynthetic photon flux density (PPFD), in micromoles per square meter per second (µmol/m²/s). The guide cautions that lux and lumens are weighted for human vision and are not substitutes for a horticultural measurement of photosynthetically active radiation. It says conditions in an operating facility may differ from a lighting plan because of fixture aging, environmental conditions or installation inconsistencies.
The guide says measurements across the growing area can reveal dark zones and uneven distribution, even where average intensity appears adequate. It identifies fixture layout, mounting height and structural obstructions as possible contributors. It also says spectral measurements can help growers assess light quality and develop cultivar-specific lighting approaches for traits such as color, flavor and flowering response.
For repeatable readings, P.L. Light Systems recommends a professional-grade, calibrated light meter or spectrometer and a consistent measurement method. The guide names the LI-COR LI-180 Spectrometer as an example of an instrument that measures intensity and spectral quality and produces data and graphs for tracking changes. It says regular records can help monitor depreciation and may support a warranty service or replacement request. This advice comes from a lighting-system manufacturer; the guide does not report independent testing of the example instrument.
Measure light where crops grow Track intensity and spectrum
P.L. Light Systems recommends measuring supplemental light at plant level, since fixture plans alone cannot confirm what crops receive. Consistent readings can help growers spot uneven coverage and changing performance.
Measure quantity and quality
The guide distinguishes how much usable light reaches plants from how that light is distributed across wavelengths.
- Measure photosynthetic photon flux density (PPFD).
- Check readings across the growing area for dark zones.
- Assess light quality across wavelengths.
- Use readings to inform cultivar-specific lighting approaches.
Choose suitable instruments
Use a calibrated, professional-grade meter or spectrometer and follow its instructions.
Horticultural readings
Lux and lumens are weighted for human vision, so the guide says they are not substitutes for PPFD.
LI-COR LI-180
The guide names this spectrometer as an example that measures intensity and spectral quality.
Make readings repeatable
The supplied guidance leaves sampling details and measurement frequency to each facility.
Document where and how readings are taken.
Track intensity and spectral data at comparable locations.
Review fixture placement and installation if readings show decline or uneven coverage.
Know what readings can show
Measurements can support practical decisions, but the guide leaves important limits open.
| Readings may help | They do not establish |
|---|---|
| Find dark zones and uneven distribution | A universal measurement schedule |
| Monitor performance changes over time | Independent validation of the example instrument |
| Document information for a manufacturer | Warranty eligibility or a guaranteed yield effect |
Why Greenhouse Light Checks Matter
P.L. Light Systems’ guide says supplemental lighting is used to support consistent growing conditions and influence crop development. When actual output differs from the planned output, growers may make decisions based on a lighting layout that no longer reflects conditions at plant level. Measured readings can expose gaps that might otherwise be missed, including spatial differences between crop rows or sections of a greenhouse.
The guide recommends tracking both intensity and spectrum to compare conditions over time, rather than treating fixture performance as fixed. That can inform maintenance planning and help growers evaluate whether a lighting recipe is delivering the intended conditions. It states that a 1% reduction in light corresponds to roughly a 1% yield loss, but provides no supporting study, crop details or measurement basis for that estimate. It should be read as the company’s stated rule of thumb, not a guaranteed relationship for every crop or facility.
Products Worth Considering

Solo Stove Pi Prime Portable Propane Pizza Oven

AMERLIFE 34 × 10 × 7 ft Walk-In Tunnel Greenhouse with Watering System

Orbit B-hyve XR 16-Zone Indoor/Outdoor Smart Sprinkler Controller
As an affiliate, we earn on qualifying purchases.
From Fixture Plans to Crop-Level Readings
P.L. Light Systems’ guide explains that a fixture’s specified output or a design plan describes expected performance, but does not by itself confirm the light reaching plants after installation or during operation. It points to aging and installation variation as reasons to check the real-world result. The guide also notes that a measurement taken at one point may not show how light varies across the growing space, which is why it emphasizes checking distribution.
The guide distinguishes intensity from spectrum: intensity addresses how much photosynthetically relevant light reaches a measurement area, while spectral output describes how that light is distributed across wavelengths. Its recommendation to record both is intended to help growers understand quantity, quality and change over time. The supplied guidance does not lay out a full protocol, such as exact sensor positions, sampling intervals or the frequency of repeat measurements.
Details the Guide Leaves Open
The published P.L. Light Systems guidance does not specify how often growers should take readings, how many locations to sample, or the precise height and orientation for a meter. It points readers to further information on protocols and common challenges, but those details are not included in the supplied text. Growers will need a consistent method suited to their facility and should follow their instrument’s instructions.
The article also does not provide comparative test results, independent validation of the named spectrometer, or crop-specific evidence for the stated light-to-yield estimate. It is therefore unclear how the recommendations perform across different crops, greenhouse designs and lighting technologies. Warranty coverage and eligibility depend on the fixture maker’s terms and documented conditions; measurements alone do not establish that a product qualifies for service.
Set a Repeatable Measurement Plan
Growers looking to apply the guidance can start by selecting an appropriate, calibrated instrument and documenting where and how readings are taken. Repeating measurements at comparable locations and recording intensity and spectral data can help distinguish normal variation from changes that may warrant investigation. P.L. Light Systems’ article does not prescribe a particular schedule, so facilities must set one that fits their crops, operations and equipment.
If readings suggest declining output or uneven coverage, possible next steps include checking installation conditions, reviewing fixture placement and consulting the lighting manufacturer. Growers considering a warranty claim should retain dated measurements and consult the applicable warranty terms. P.L. Light Systems directs readers to its website for further guidance on measurement protocols and common challenges.
Source: rss
Key Questions
What unit should growers use to measure plant light?
The P.L. Light Systems guide identifies PPFD in micromoles per square meter per second (µmol/m²/s) as the measure of photosynthetically relevant light. It says lux and lumens are based on human vision and should not be used as substitutes for horticultural readings.
Why measure light across more than one location?
The guide says readings across a growing area can reveal dark or shadowed zones that an average intensity reading might conceal. It identifies fixture layout, mounting height and structural obstructions as possible contributors to uneven coverage.
Do growers need a spectrometer?
The guide recommends a calibrated, professional-grade light meter or spectrometer. It says a spectrometer can measure intensity and spectral quality; the appropriate instrument depends on what a grower needs to monitor.
How often should light readings be taken?
The guidance does not set a measurement frequency. It recommends regular monitoring and consistent methods, but leaves the schedule to growers and does not specify sampling intervals or locations.
Can measurements prove a fixture is covered by warranty?
According to the guide, measurements can document performance over time and may be useful when contacting a manufacturer. They do not by themselves confirm coverage; warranty eligibility depends on the applicable terms.
Source: greenhousegrower.com